Ready Capacity Drops Below Desired¶
Symptom¶
deployment.spec.replicas still shows the desired count, but readyReplicas or availableReplicas dips during node loss, zonal impairment, replacement image pull failure, unschedulable recovery, or autoscaler lag.
Possible Causes¶
- A node crash or node pool impairment removed running pods faster than replacement pods could start.
- A zonal incident reduced available nodes in one failure domain and the workload could not rebalance immediately.
- Replacement pods exist but cannot become Ready because of image pull failure, probe failure, or missing capacity.
- The cluster autoscaler is enabled, but recovery takes longer than the application's tolerance window.
- The workload relies on PDBs or graceful termination to avoid a gap, even though the actual incident path is involuntary.
Diagnosis Steps¶
flowchart TD
A[Desired replicas unchanged] --> B[Compare desired ready and available counts]
B --> C[Check node loss and zonal health]
C --> D{Replacement pods created?}
D -->|No| E[Inspect scheduling and autoscaler path]
D -->|Yes| F[Inspect image pull and readiness path]
E --> G[Restore capacity or relax constraints]
F --> G -
Confirm the deployment-level gap.
-
Inspect pod placement and current readiness state.
-
Check whether a node or zone event preceded the dip.
-
If replacement pods are missing, inspect scheduling failure and autoscaler bounds.
az aks nodepool list \ --resource-group "$RG" \ --cluster-name "$CLUSTER_NAME" \ --query "[].{name:name,zones:availabilityZones,count:count,enableAutoScaling:enableAutoScaling,minCount:minCount,maxCount:maxCount}" \ --output tableCommand Purpose az aks nodepool listList node pools with zones and scaling. --resource-groupResource group that contains the AKS cluster. --cluster-nameName of the AKS cluster. --querySelects name, zones, count, and autoscaling. --outputOutput format for the result. -
If replacement pods exist but are not Ready, inspect their exact failure path.
Common pivots:
ImagePullBackOfforErrImagePull-> Image Pull Failure0/NN nodes are available-> Pending PodsNodeNotReadyor mass pod eviction after node loss -> Node Not Ready
-
Check whether the workload is expecting PDBs or graceful termination to solve an involuntary failure path.
PDBs and
preStopcan reduce some voluntary disruption paths, but they do not eliminate the gap after crashes, zone loss, image pull failure, or unschedulable replacements.
Resolution¶
- Restore lost node capacity first when the incident began with node or zone impairment.
- Fix image pull or readiness failures on replacement pods before tuning disruption settings.
- Increase replica count and spread replicas across zones if the current steady-state count cannot absorb one-node or one-zone loss.
- Reduce scheduler strictness or rebalance per-zone capacity if replacements stay pending.
- Tune autoscaler bounds and headroom so the cluster can recover fast enough for the workload's recovery objective.
Prevention¶
- Run enough replicas to survive at least one node loss without dropping below the minimum usable capacity.
- Combine spread rules, autoscaler bounds, and image delivery design so replacement pods can actually start in another zone.
- Use PDBs,
preStop, andterminationGracePeriodSecondsfor voluntary drain paths, while documenting that involuntary failure still needs spare capacity and fast replacement. - Rehearse node-loss, zonal-pressure, and image-registry failure scenarios separately.
See Also¶
- When You Need Explicit Placement and Disruption Control
- Pod Disruption Budget Drain Contract
- Node Not Ready
- Image Pull Failure
- Pending Pods